Specifications for Ultra Whisper Modular (UWM):
PERFORMANCE
 
RATED PERFORMANCE / PRODUCT WATER PRODUCED
+-15% at 841 PSI / 58 BAR, 77oF / 25oC & 35,000 PPM TDS typical sea water

Model # Per Hour Per Day Weight of System
UWM 200-1 8 gal/32 lit 200 gal /757 lit 130 lbs/59 Kg
UWM 300-1 13 gal/47 lit 300 gal/1136 lit 138 lbs/63 Kg
UWM 400-1 17 gal/63 lit 400 gal/1514 lit 145 lbs/66 Kg
UWM 500-1 21 gal/79 lit 500 gal/1893 lit 153 lbs/69 Kg
UWM 600-1 25 gal/95 lit 600 gal/2271 lit 155 lbs/70 Kg


SALT REJECTION (CHLORIDE ION)
Minimum 99.2%, Average 99.4%

PRODUCT WATER TEMPERATURE
Ambient to feed water temperature. A slight increase in the product water temperature occur due to the heat transfer from the engine room and feed pump.

SALINITY MONITORING
The system monitors the salinity of the product water continuously and compensates for temperature variations. Only potable product water is directed to the ship's potable water tanks. The product water quality is continuously displayed on the system touch pad.

SALINITY RANGE
Designed for Seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)

TEMPERATURE RANGE
Max. 91oF / 33oC, Min. 33oF / .5oC

SYSTEM FEED WATER
Flow: 50Hz, 1 - 3 gpm / 5 - 11 lpm; 60Hz, 2 - 4 gpm/ 6 - 13 lpm

REVERSE OSMOSIS MEMBRANE
High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.

CHLORINE TOLERANCE
0.01 PPM

pH RANGE
3-11 (typical seawater pH is 8)

SYSTEM PRESSURE: FEED WATER
Minimum  80 - 185 psi / 6 - 13 bar / 6 - 13 Kg/cm2
Maximum 125 - 220 psi / 9 - 15 bar / 9 - 15 Kg/cm2


SYSTEM OPERATION
Typical seawater has a salinity of 35,000 ppm TDS and an average temperature of 77oF / 25oC. Under these conditions, the system operating pressure is approximately 700 psi.

EXTERNAL INSTALLATION WATER CONNECTIONS
Pipe sizes to be supplied by the installer for connection of the Sea Recovery supplied components. The below pipe threads are all American Standard.
Feed Inlet 3/4" Female NPT Elbow
& 3/4" Male NPT x 1/2" Hose Barb Connector
Brine Discharge 1/2" Female NPT Tee
Product 1/4" Male NPT x 1/4" Tube Elbow
 
ELECTRICAL POWER REQUIREMENTS
(HP = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes - Start Up)

Alternating Current Systems:

System Hz VAC HP FLA LRA Hz VAC HP FLA LRA
UWM 200 gpd 50 115 .33 6 10 60 115 .33 6 9
UWM 200 gpd 50 230 .33 3 5.3 60 230 .33 3 4
UWM 400 gpd 50 115 .33 9 14 60 115 .33 7 12
UWM 400 gpd 50 230 .33 4 7 60 230 .33 4 6
UWM 600 gpd 50 115 .5 12 21 60 115 .5 10 19
UWM 600 gpd 50 230 .5 6 10 60 230 .5 5 8

Direct Current Systems:

System VDC HP FLA
UWM 200 gpd 12 .125 9
UWM 200 gpd 24 .125 5
UWM 400 gpd 12 .33 22
UWM 400 gpd 24 .33 11

RECOMMENDED CIRCUIT BREAKER:
Operating Voltage  Circuit Protection Wire Size AWG (min) 
UWM 200 GPD
12 VDC 20 Amps 14 AWG
24 VDC  10 Amps 14 AWG
115 VAC 10 Amps 14 AWG
230 VAC 6 Amps 14 AWG
12 VDC 10 Amps 16 AWG
UWM 400 GPD
12 VDC 60 Amps 8 AWG
24 VDC 30 Amps 10 AWG
115 VAC 20 Amps 14 AWG
230 VAC 10 Amps 14 AWG
12 VDC 10 Amps 16 AWG
UWM 600 GPD
115 VAC 22 Amps 14 AWG
12 VDC 10 Amps 16 AWG
220 VAC 12 Amps 14 AWG