| Specifications for Aqua Whisper
Frame (AWF): |
PERFORMANCE:
|
RATED PERFORMANCE / PRODUCT WATER PRODUCED:
|
+-15% at 820 PSI / 57 BAR, 77oF / 25oC
& 35,000 PPM TDS typical sea water
|
| Model # |
Per Hour |
Per Day |
Weight of System |
| AWF 450-1 |
19 gal/71 lit |
450 gal /1,703
lit |
147 lbs/67 Kg |
| AWF 700-1 |
29 gal/110 lit |
700 gal/2,650
lit |
150 lbs/68 Kg |
| AWF 900-1 |
38 gal/142 lit |
900 gal/3,407
lit |
152 lbs/69 Kg |
| AWF 900-2 |
38 gal/142 lit |
900 gal/3,407
lit |
159 lbs/72 Kg |
| AWF 1400-2 |
58 gal/221 lit |
1400 gal/5,300
lit |
165 lbs/75 Kg |
| AWF 1800-2 |
75 gal/284 lit |
1800 gal/6,814
lit |
170 lbs/77 Kg |
|
| |

|
| SALT REJECTION (CHLORIDE ION): |
Minimum 99.2%, Average 99.4%
|
| PRODUCT WATER TEMPERATURE |
Ambient to feed water temperature
|
| SALINITY MONITORING |
Automatic electronic monitoring. Temperature
compensated with the solid state continuous
"Bar LED" readout. The salinity
monitoring components of the system give
a continuous TDS readout in micromhos per
cubic centimeter, are temperature compensated
and of a fail safe design
|
| SALINITY RANGE |
Designed for Seawater use up to 50,000
PPM TDS (NaCl) (typical seawater salinity
is 35,000 ppm)
|
| TEMPERATURE RANGE |
Max. 122oF / 50oC, Min. 33oF / .5oC
|
| SYSTEM FEED WATER: FLOW |
3.0 - 4.2 gpm / 11.4 - 15.9 lpm (depending
on system) |
| REVERSE OSMOSIS MEMBRANE |
Selected High Rejection/High Yield aromatic
tri-polyamid, thin film composite, spiral
wound, single pass, high rejection reverse
osmosis membrane element. |
| CHLORINE TOLERANCE |
0.1 PPM |
| pH RANGE |
3-11 (typical seawater pH is 8) |
| SYSTEM PRESSURE: FEED WATER |
Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2
|
| SYSTEM OPERATION: |
Seawater nominal 820 psi / 56.5 bar /
57.66 Kg/cm2 Brackish Varies w/PPM
|
| EXTERNAL INSTALLATION WATER CONNECTIONS |
Pipe sizes to be supplied by the installer
for connection of the Sea Recovery supplied
components. The below pipe threads are all
American Standard. |
| Feed Inlet: |
3/4" FNPT Female National
Pipe Thread |
| Brine Discharge: |
1/2" FNPT Female National
Pipe Thread |
| Product: |
3/8" MNPT Male National Pipe
Thread |
|
| ELECTRICAL POWER REQUIREMENTS |
(HP = Horse Power; FLA = Full Load Amperes;
LRA = Locked Rotor Amperes - Start Up)
|
| HIGH PRESSURE PUMP ELECTRIC MOTOR |
| Models 450-1 & 900-2: |
| Phase |
Hz |
VAC |
HP |
FLA |
LRA |
| Single |
50 |
110 |
2.2 |
21 |
121 |
| Single |
50 |
220 |
2.2 |
11 |
61 |
| Three |
50 |
220 |
3.0 |
9 |
78 |
| Three |
50 |
380 |
3.0 |
5 |
39 |
| Single |
60 |
115 |
2.2 |
18 |
94 |
| Single |
60 |
230 |
2.2 |
9 |
47 |
| Three |
60 |
230 |
3.0 |
8 |
70 |
| Three |
60 |
460 |
3.0 |
4 |
35 |
|
| Models 700-1 & 1400-2, and 900-1 &
1800-2 |
| Phase |
Hz |
VAC |
HP |
FLA |
LRA |
| Single |
50 |
110 |
2.2 |
21 |
121 |
| Single |
50 |
220 |
2.2 |
11 |
61 |
| Three |
50 |
220 |
3.0 |
9 |
78 |
| Three |
50 |
380 |
3.0 |
5 |
39 |
| Single |
60 |
115 |
2.6 |
21 |
109 |
| Single |
60 |
230 |
2.6 |
11 |
55 |
| Three |
60 |
230 |
3.0 |
8 |
70 |
| Three |
60 |
460 |
3.0 |
4 |
35 |
|
| BOOSTER PUMP & FEED WATER ELECTRIC
MOTORS: |
| Phase |
Hz |
VAC |
HP |
FLA |
LRA |
| Single |
50/60 |
115 |
1/2 |
7.4 |
34 |
| Single |
50/60 |
220/230 |
1/2 |
3.7 |
17 |
| Three |
50/60 |
220/230 |
1/2 |
2 |
12 |
| Three |
50/60 |
380/460 |
1/2 |
1 |
6 |
|
| RECOMMENDED CIRCUIT BREAKER |
The final system configuration may have
a large or different size Booster Pump therefore
size your Circuit Breaker accordingly. The
below chart is an approximation assuming
standard pumps. |
| Operating Voltage Hz
& Phase |
Recommended Circuit
Breaker Size |
| 115 VAC, 50 Hz, Single
Phase |
35 Amperes |
| 230 VAC, 50 Hz, Single
Phase |
15 Amperes |
| 208/230 VAC, 50 Hz,
Three Phase |
10 Amperes |
| 380 VAC, 50 Hz, Three
Phase |
7.5 Amperes |
| 460 VAC, 50 Hz, Three
Phase |
7.5 Amperes |
|