Features
Unit Design
- Compact design reduces unit size upto 25% of the
original vector Rotary’s size. Now even more compact
- the new 2003 redesign reduces the size of 10-16K
units even further, approximately one inch in both
width and depth.
- Return air filters are now included, and
are held in place by new filter rails.
- Patented design #5,848,536 provides increased
gross cooling capacity and increased dehumidification.
- Unique compressor and reversing valve mounting reduces
vibration.
- Built-in carrying handle provides ease of installation.
- Blowers are fully insulated and rotatable.
- Passport I/O circuit board operates the new Elite™
and Passport I/O displays (model VCD only). Controls
are sold separately.
Electrical Box
- Electrical box is installed on unit, within
the footprint dimensions, eliminating additional installation
labor and space required.
- Completely enclosed, water resistant box protects
electrical components.
- Internal field wiring connections meet CE Low Voltage
directive.
High Efficiency Components
- High efficiency compressors provide reduced
amperage, quieter operation, less weight and increased
reliability.
- Condenser coil constructed of spiral, fluted cupronickel
encased in a copper shell provides maximum heat transfer
and high corrosion resistance to seawater flow.
- Evaporator coil utilizes enhanced fin design and
rifled copper tubing provides maximum capacity.
- There are two compact models in the self-contained
Vector Compact Series - VCD and VCM. Each uses a different
control. For details, see specifications.
Quality Assurance
- Three year limited warranty when used
with the Elite or Passport I/O Controls.
- Each unit is pre-charged, leak checked and test
run in all operating modes.
- Charge Guard® protection provides sealed access
ports, ensuring environmental protection and system
integrity.
- All units meet or exceed applicable ABYC and U.S.
Coast Guard regulations, CE Directives and general
Air Conditioning and Refrigeration Industry (ARI)
standards.
SPECIFICATIONS
| Model (1)
|
VC*5K/
1 |
VC*7K/
1 |
VC*10K/
1 |
VC*12K/
1 |
VC*16K/
1 |
VC*24K
/1(4) |
| Capacity (BTU/H)(2)
|
5,000 |
7,000 |
10,000 |
12,000 |
16,000 |
24,000 |
| Voltage(VAC) |
115 |
220-240 |
115 |
230 |
220-240 |
115 |
230 |
220-240 |
115 |
230 |
220-240 |
115 |
230 |
220-240 |
230 |
220-224 |
| Cycle (Hz)(3) |
60 |
50 |
60 |
60 |
50 |
60 |
60 |
50 |
60 |
60 |
50 |
60 |
60 |
50 |
60 |
50 |
| Full Load Amps (FLA) cool(2)
|
5.2 |
2.7 |
6.3 |
2.8 |
3.2 |
8.9 |
4.2 |
4.5 |
10.9 |
4.9 |
4.8 |
11.7 |
5.8 |
5.7 |
7.1 |
8.1 |
| Full Load Amps (FLA) heat (2)
|
6.3 |
3.2 |
7.8 |
3.6 |
3.7 |
11.1 |
5.3 |
5.3 |
12.9 |
6.0 |
5.8 |
14.7 |
7.2 |
7.0 |
9.7 |
10.6 |
| Locked Rotor Amps(Comp) (2)
|
30.1 |
17.7 |
36.2 |
17.7 |
16.5 |
45.6 |
22.2 |
22.2 |
58.4 |
27.9 |
22.2 |
67.0 |
29.0 |
32.0 |
54.0 |
56.0 |
| K.V.A. (Kilo-Volt-Amps) (2)
|
0.7 |
0.8 |
0.9 |
0.9 |
0.9 |
1.3 |
1.2 |
1.3 |
1.5 |
1.4 |
1.4 |
1.7 |
1.7 |
1.7 |
2.2 |
2.5 |
| Max. Circuit Breaker (Amps) (2)
|
15 |
10 |
20 |
10 |
10 |
30 |
15 |
15 |
40 |
20 |
15 |
40 |
20 |
20 |
35 |
40 |
| Min. Circuit Ampacity (Amps) (2)
|
11 |
7 |
14 |
7 |
7 |
19 |
9 |
10 |
24 |
12 |
10 |
26 |
14 |
13 |
21 |
24 |
| Refrigerant R-22 (oz/g) (5)
|
8.0
/227 |
10.0/
283 |
10.5/
298 |
11.0/
312 |
15.0/
425 |
16.0/
454 |
| |
| Unit Dimensions (in/mm) |
| Height - Evaporator |
11.25 /
286 |
11.50 /
292 |
12.25 /
311 |
13.00 /
330 |
13.63 /
346 |
18.00 / 457 |
| Height - Blower (6) |
10.50 /
267 |
12.25 /
311 |
13.50 /
343 |
13.63 /
346 |
13.63 /
346 |
19.25 / 489 |
| Width |
16.50/
419 |
18.00 /
457 |
19.25 /
489 |
19.25 /
489 |
19.25 /
489 |
24.75 / 629 |
| Depth |
9.00 /
229 |
9.63 /
245 |
9.63 /
245 |
9.63 /
245 |
11.38 /
289 |
15.25 / 387 |
| Motor Overhang |
3.75 /
95 |
3.25 /
83 |
3.75 /
95 |
3.75 /
95 |
4.00 /
102 |
3.50 /
89 |
| Min. Duct Size Dia. |
4 /
102 |
5 /
127 |
6 /
152 |
6 /
152 |
7 /
178 |
8 /
203 |
| Net Weight (lbs . kg) |
42.0 /
19.1 |
48.7 /
22.0 |
54.3 /
24.6 |
56.3 /
25.5 |
63.8 /
28.9 |
120.0 / 54.4 |
| Gross Weight (lbs/ kg) |
51.4 /
23.3 |
58.0 /
26.3 |
63.0 /
28.6 |
65.0 /
29.5 |
73.0 /
33.1 |
130.0 / 58.9 |
- Add a 'Z' or 'Z50' before the
"/1" in the model number for 230V or 220 V
/ 50 Hz units respectively. Examples VCD7K/1 = 230 V
, VCD7K50/1 = 220V/50Hz.
- BTU and electrical data are based on
a 45°F / 7.2 °C evaporator 100°F / 37.8 °C condenser
in cool mode, and a 45°F / 7.2 °C evaporator and 130°F
/ 54.4 °C condenser in heat.
- Standard 60 Hz units must be used. Note
: 50 Hz units must not operate at 60 Hz.
- Contains high efficiency scroll compressor.
- Alternate "Environmetally Friendly
Green Gas" refrigerants available on request.
- Blower may be rotated downward to below
evaporator height.
- The depth of the VC - 10K -HV and VC
- 12K - HV is 10.50 / 267 (in / mm).
- Motor is inside blower on HV units, however,
allow 1.00 /25 (in / mm) for blower ring flange
on that side.
*D = Elite or Passport I/O Control (VCD), M = Mechanical Control (VCM)
|
|
|