www.oceanoptions.com
   :: Home
   :: About Us
   :: Products
   :: New Products
   :: Technical Support
   :: Dealer Locator
   :: Contact

Vector Compact
(Marine Air Systems)

Click here to view Installation Guide


Features
Unit Design

  • Compact design reduces unit size upto 25% of the original vector Rotary’s size. Now even more compact - the new 2003 redesign reduces the size of 10-16K units even further, approximately one inch in both width and depth.
  • Return air filters are now included, and are held in place by new filter rails.
  • Patented design #5,848,536 provides increased gross cooling capacity and increased dehumidification.
  • Unique compressor and reversing valve mounting reduces vibration.
  • Built-in carrying handle provides ease of installation.
  • Blowers are fully insulated and rotatable.
  • Passport I/O circuit board operates the new Elite™ and Passport I/O displays (model VCD only). Controls are sold separately.
Electrical Box
  • Electrical box is installed on unit, within the footprint dimensions, eliminating additional installation labor and space required.
  • Completely enclosed, water resistant box protects electrical components.
  • Internal field wiring connections meet CE Low Voltage directive.
High Efficiency Components
  • High efficiency compressors provide reduced amperage, quieter operation, less weight and increased reliability.
  • Condenser coil constructed of spiral, fluted cupronickel encased in a copper shell provides maximum heat transfer and high corrosion resistance to seawater flow.
  • Evaporator coil utilizes enhanced fin design and rifled copper tubing provides maximum capacity.
  • There are two compact models in the self-contained Vector Compact Series - VCD and VCM. Each uses a different control. For details, see specifications.
Quality Assurance
  • Three year limited warranty when used with the Elite or Passport I/O Controls.
  • Each unit is pre-charged, leak checked and test run in all operating modes.
  • Charge Guard® protection provides sealed access ports, ensuring environmental protection and system integrity.
  • All units meet or exceed applicable ABYC and U.S. Coast Guard regulations, CE Directives and general Air Conditioning and Refrigeration Industry (ARI) standards.


 
SPECIFICATIONS

Model (1) VC*5K/
1
VC*7K/
1
VC*10K/
1
VC*12K/
1
VC*16K/
1
VC*24K
/1(4)
Capacity (BTU/H)(2) 5,000 7,000 10,000 12,000 16,000 24,000
Voltage(VAC) 115 220-240 115 230 220-240 115 230 220-240 115 230 220-240 115 230 220-240 230 220-224
Cycle (Hz)(3) 60 50 60 60 50 60 60 50 60 60 50 60 60 50 60 50
Full Load Amps (FLA) cool(2) 5.2 2.7 6.3 2.8 3.2 8.9 4.2 4.5 10.9 4.9 4.8 11.7 5.8 5.7 7.1 8.1
Full Load Amps (FLA) heat (2) 6.3 3.2 7.8 3.6 3.7 11.1 5.3 5.3 12.9 6.0 5.8 14.7 7.2 7.0 9.7 10.6
Locked Rotor Amps(Comp) (2) 30.1 17.7 36.2 17.7 16.5 45.6 22.2 22.2 58.4 27.9 22.2 67.0 29.0 32.0 54.0 56.0
K.V.A. (Kilo-Volt-Amps) (2) 0.7 0.8 0.9 0.9 0.9 1.3 1.2 1.3 1.5 1.4 1.4 1.7 1.7 1.7 2.2 2.5
Max. Circuit Breaker (Amps) (2) 15 10 20 10 10 30 15 15 40 20 15 40 20 20 35 40
Min. Circuit Ampacity (Amps) (2) 11 7 14 7 7 19 9 10 24 12 10 26 14 13 21 24
Refrigerant R-22 (oz/g) (5) 8.0
/227
10.0/
283
10.5/
298
11.0/
312
15.0/
425
16.0/
454
 
Unit Dimensions (in/mm)
Height - Evaporator 11.25 /
286
11.50 /
292
12.25 /
311
13.00 /
330
13.63 /
346
18.00 / 457
Height - Blower (6) 10.50 /
267
12.25 /
311
13.50 /
343
13.63 /
346
13.63 /
346
19.25 / 489
Width 16.50/
419
18.00 /
457
19.25 /
489
19.25 /
489
19.25 /
489
24.75 / 629
Depth 9.00 /
229
9.63 /
245
9.63 /
245
9.63 /
245
11.38 /
289
15.25 / 387
Motor Overhang 3.75 /
95
3.25 /
83
3.75 /
95
3.75 /
95
4.00 /
102
3.50 /
89
Min. Duct Size Dia. 4 /
102
5 /
127
6 /
152
6 /
152
7 /
178
8 /
203
Net Weight (lbs . kg) 42.0 /
19.1
48.7 /
22.0
54.3 /
24.6
56.3 /
25.5
63.8 /
28.9
120.0 / 54.4
Gross Weight (lbs/ kg) 51.4 /
23.3
58.0 /
26.3
63.0 /
28.6
65.0 /
29.5
73.0 /
33.1
130.0 / 58.9

  1. Add a 'Z' or 'Z50' before the "/1" in the model number for 230V or 220 V / 50 Hz units respectively. Examples VCD7K/1 = 230 V , VCD7K50/1 = 220V/50Hz.
  2. BTU and electrical data are based on a 45°F / 7.2 °C evaporator 100°F / 37.8 °C condenser in cool mode, and a 45°F / 7.2 °C evaporator and 130°F / 54.4 °C condenser in heat.
  3. Standard 60 Hz units must be used. Note : 50 Hz units must not operate at 60 Hz.
  4. Contains high efficiency scroll compressor.
  5. Alternate "Environmetally Friendly Green Gas" refrigerants available on request.
  6. Blower may be rotated downward to below evaporator height.
  7. The depth of the VC - 10K -HV and VC - 12K - HV is 10.50 / 267 (in / mm).
  8. Motor is inside blower on HV units, however, allow 1.00 /25 (in / mm) for blower ring flange on that side.

*D = Elite or Passport I/O Control (VCD), M = Mechanical Control (VCM)
Developed by BF Enterprises