www.oceanoptions.com
   :: Home
   :: About Us
   :: Products
   :: New Products
   :: Technical Support
   :: Dealer Locator
   :: Contact

Slim Line Air Handlers
(Marine Air Systems)

Click here to view Installation Guide


Features
Modular Design

  • White aluminium construction
  • Modules can be installed in either vertical or horizontal configurations.
  • Flexible design allows for alternate supply and return air locations.
  • Pre-plumbed right AND left, use either / or
Blower Assembly Side
  • Permanent split capacitor motors for quiet, efficient operation.
  • Fire retardant plastic blower housings.
  • Framed filters are made of washable, fire retardant materials. Filters are attached to unit by stainless steel, "snapping" mount clips.
  • Optional auxiliary heting elements for additional heat capacity.
Fan Coil Assembly Side
  • Enclosed insulated draindrain pan threaded, dual drain connections for complete condensate removal.
  • Fully insulated cabinetry.
  • Internal 3-way valve assembly, with air bleeder.
Quality Assurance
  • System matched components assure full BTU rating.
  • All units meet or exceed applicable ABYC and U.S. Coast Guard regulations, CE Directives and general Air Conditioning and Refrigeration Industry (ARI) standards.

SPECIFICATIONS

Model AH6K-SL2M AH9K-SL2M AH12K-SL2M AH18K-
SLM
AH24K-
SLM
AH30K-
SLM
AH36K-
SLM
Capacity (BTU/H) / (Kcal/H) 6,000/
1,512
9,000/
2,268
12,000/
3,024
18,000/
14,536
24,000/
6,048
30,000/
7,560
36,000/
9,072
Voltage / Cycle / Phase 230-208 VAC / 60 Hz / 1Ø -------- 220-200 VAC / 50Hz / 1Ø
Amperage 0.8 0.8 0.8 0.8 0.8 0.8 1.6
GPM / (liters/min.) 1.5/
5.7
2.25/
8.5
3.0/
11.4
4.5/
17.0
6.0/
22.7
7.5/
28.4
9.0/
34.1
CFM/(M3/Hr.) 200/
340
300/
509
400/
679
600/
1,019
750/
1,274
1,000/
1,698
1,200/
2,038
Auxiliary Heating Elements
Element Size(KW) 1.0 1.0 1.5 3.0 3.0 4.5 4.5
Rating (BTU/H)(Kcal/H) 3,415/
861
3,415/
861
5,123/
861
10,245/
2,582
10,245/
2,582
15,368/
3,873
15,368/
3,873
Amperage(230 VAC) 4.3 4.3 6.5 13.0 13.0 19.5 19.5
Max. Fuse Size/Min. Circuit Ampacity
Without Heating Element 5.0/
1.0
5.0/
1.0
5.0/
1.0
5.0/
1.0
5.0/
1.0
5.0/
2.0
5.0/
2.0
With Heating Element 10.6/
6.0
10.6/
6.0
10.0/
9.0
15.0/
14.5
15.0/
14.5
30.0/
26.0
30.2/
26.0
Dimensions (in/cm)
A (Length) 20.75 / 52.7 24.75/
62.9
32.75/
83.2
38.75/
98.4
44.75/
113.7
55.75/
141.6
62.75/
159.4
B (Depth)(2) 10.5/
26.7
10.5/
26.7
10.5/
26.7
10.5/
26.7
10.5/
26.7
10.5/
26.7
10.5/
26.7
C (Overall Height)(2) 21.0/
53.3
21.0/
53.3
21.0/
53.3
21.0/
53.3
21.0/
53.3
21.0/
53.3
21.0/
53.3
D (Unit Height) 22.0/
55.9
22.0/
55.9
22.0/
55.9
22.0/
55.9
22.0/
55.9
22.0/
55.9
22.0/
55.9
E (Discharge Flange) 1.0/
2.5
1.0/
2.5
1.0/
2.5
1.0/
2.5
1.0/
2.5
1.0/
2.5
1.0/
2.5
F (Discharge Opening-Depth) 4.0/
10.2
4.0/
10.2
4.0/
10.2
4.0/
10.2
4.0/
10.2
4.0/
10.2
4.0/
10.2
G (Discharge Opening-Lenght) 12.0/
30.5
16.0/
40.6
24.0/
61.0
30.0/
76.2
36.0/
91.4
47.0/
119.4
54.0/
137.2
H (Return Air Grille-Height) 7.25/
18.4
7.25/
18.4
7.25/
18.4
7.25/
18.4
7.25/
18.4
7.25/
18.4
7.25/
18.4
I (Return Air Grille-Lenght) 15.0/
38.1
19.0/
48.3
27.0/
68.6
33.0/
83.8
39.0/
99.1
50.0/
127.0
57.0/
144.8
O (Circulation Water Inlet/Outlet) 0.5" FPT brass with 0.625" HB brass 0.75" FPT/HB 0.75" FPT/HB 1.0" FPT/HB 1.0" FPT/HB
P (Condensate Drains) 2 @ 0.625" Ø x 2" long pipe
Weight (lbs / kg) 41/18.6 51/23.2 55/25 68/31 70/32 88/40 90/41

  1. Auxiliary heating elements are optional, and must be ordered with unit. Above sizes are maximum values for each model. Smaller elements may be applied to all units.
  2. Dimensions are for vertical configurations. For horizontal configurations, reverse depth (B) and height (C) dimensions.

Developed by BF Enterprises