Product Description
The Passport ® I/O Environmental Control
Unit is a microprocessor based controller designed
for the precise monitoring of split and self-contained
direct expansion air conditioning systems in marine
environments. The control operated at 115 or 230 volts,
each operable at 50 or 60 cycles.
The assembly has ground shield to protect against
static interference and RF noise. The circuit board
is comformally coated to provide high resistance to
external damage or corrosion.
A display cable with gold plated phone-type modular
jacks connects the panel to the system controller.
An optional air sensor cable is connected to circuit
board in the same manner. Non-volatile memory stores
all user-selectable parameters indefinitely during
operations or any power failure situations.
Internal self-diagnostic programs provide complete
electronic checks of all lights, sensors, keys and
circuits. Fused circuits and M.O.V.s (metal oxide
varistors) provide component and board protection.
The Passport I/O control meets or exceeds applicable
ABYC, U.S. Coast Guard REgualtions and CE Directives.
Features
- Automatic humidity control - reduces moisture when the boat is unattended.
- Cool only, heat only, or automatic mose selection.
- Temperature displayed in Fahrenheit or Celcius.
- Multiple fan speed selections - automatic or six manual speeds.
- Cycle fan with compressor or continous fan operation.
- Compressor time delay staging for multiple unit applications.
- Calibration of fan speed settings and temperature display to maintain precise control.
- Blank display lights when desired.
- Controls shaded pole and split capacitor fan motors.
- Compressor fail-safe protection.
- Programmable de-icing cycle.
Design Features
- Low oltage for optimum safety.
- Built-in air sensor (optional remote sensor).
- Universal symbols with tactile switches and embossed power key-international recognition.
- Cabin temperature is continously displayed.
- Lexan face plate available in black with cameo graphics.
Installation
- The circuit board and display cable are factory installed in the electrical box.(3)
- Display panels can be mounted with adhesive strips, or use screws with optional, soft bulkhead adaptor.
- Easy connections using phone-type modular jacks which are shielded and grounded.
SPECIFICATIONS
| Model |
PASSPORT I/O |
| Voltage(VAC) |
115 |
230 |
| Cycle(Hz) |
50/60 |
50/60 |
| Phase(Ø) |
1 |
1 |
| |
|
|
| Circuits(1) |
| Compressor
Output(2) |
40A-115VAC |
20A-230VAC |
| R.V. Output(3) |
6A-115VAC |
6A-230VAC |
| Fan Ouput |
6A-115VAC |
6A-230VAC |
| Electric
Heat Output |
30A-115VAC |
15A-230VAC |
| |
| Temperature
Ranges°F(°C) |
| Set Point
Temperature |
65-85(18-29) |
| Display
Temperature |
0-150(-18-66) |
| Air Sensor
Temperature |
0-150(-18-66) |
| Sensor
Accuracy |
±2°F
at 77 °C (±3.6°Cat 25°C) |
| |
| Dimensions
in(cm) |
| Display
Panel |
4.50(11.4) W
x 3.88(9.9)H x .088(2.2)D |
| Cut-Out |
3.375(8.6)W
x 2.875(7.3)H |
| |
| Cables
Included(4) |
| Display
ft(m) |
VCD: 15(4.6)
CMCD: 10(3.0) CSD:30(9.1) Chiiled Water: 15(4.6) |
| Water
Inlet Sensor |
7' (2.1m) cables
included with some AH-Elite & AH-Passport
I/O kits. |
- Maximum loads should not exceed 85% of listed output ratings.
- Maximum length for display and air sensor cables is 75'.
Maximum length for water inlet sensor cable is 75'.
- 30' display cables on central systems, 15' with Vector Compacts®, and 10' with Cabin Mates.
|