Elite Environmental Control Unit

(Marine Air Systems)

Click here to view Installation Guide


Product Description

The Passport ® I/O Environmental Control Unit is a microprocessor based controller designed for the precise monitoring of split and self-contained direct expansion air conditioning systems in marine environments. The control operated at 115 or 230 volts, each operable at 50 or 60 cycles.

The assembly has ground shield to protect against static interference and RF noise. The circuit board is comformally coated to provide high resistance to external damage or corrosion.

A display cable with gold plated phone-type modular jacks connects the panel to the system controller. An optional air sensor cable is connected to circuit board in the same manner. Non-volatile memory stores all user-selectable parameters indefinitely during operations or any power failure situations.

Internal self-diagnostic programs provide complete electronic checks of all lights, sensors, keys and circuits. Fused circuits and M.O.V.s (metal oxide varistors) provide component and board protection.

The Passport I/O control meets or exceeds applicable ABYC, U.S. Coast Guard REgualtions and CE Directives.

Features

  • Automatic humidity control - reduces moisture when the boat is unattended.
  • Cool only, heat only, or automatic mose selection.
  • Temperature displayed in Fahrenheit or Celcius.
  • Multiple fan speed selections - automatic or six manual speeds.
  • Cycle fan with compressor or continous fan operation.
  • Compressor time delay staging for multiple unit applications.
  • Calibration of fan speed settings and temperature display to maintain precise control.
  • Blank display lights when desired.
  • Controls shaded pole and split capacitor fan motors.
  • Compressor fail-safe protection.
  • Programmable de-icing cycle.
Design Features
  • Low oltage for optimum safety.
  • Built-in air sensor (optional remote sensor).
  • Universal symbols with tactile switches and embossed power key-international recognition.
  • Cabin temperature is continously displayed.
  • Lexan face plate available in black with cameo graphics.
Installation
  • The circuit board and display cable are factory installed in the electrical box.(3)
  • Display panels can be mounted with adhesive strips, or use screws with optional, soft bulkhead adaptor.
  • Easy connections using phone-type modular jacks which are shielded and grounded.
SPECIFICATIONS

Model PASSPORT I/O
Voltage(VAC) 115 230
Cycle(Hz) 50/60 50/60
Phase(Ø) 1 1
     
Circuits(1)
Compressor Output(2) 40A-115VAC 20A-230VAC
R.V. Output(3) 6A-115VAC 6A-230VAC
Fan Ouput 6A-115VAC 6A-230VAC
Electric Heat Output 30A-115VAC 15A-230VAC
 
Temperature Ranges°F(°C)
Set Point Temperature 65-85(18-29)
Display Temperature 0-150(-18-66)
Air Sensor Temperature 0-150(-18-66)
Sensor Accuracy ±2°F at 77 °C (±3.6°Cat 25°C)
 
Dimensions in(cm)
Display Panel 4.50(11.4) W x 3.88(9.9)H x .088(2.2)D
Cut-Out 3.375(8.6)W x 2.875(7.3)H
 
Cables Included(4)
Display ft(m) VCD: 15(4.6) CMCD: 10(3.0) CSD:30(9.1) Chiiled Water: 15(4.6)
Water Inlet Sensor 7' (2.1m) cables included with some AH-Elite & AH-Passport I/O kits.

  1. Maximum loads should not exceed 85% of listed output ratings.
  2. Maximum length for display and air sensor cables is 75'.
    Maximum length for water inlet sensor cable is 75'.
  3. 30' display cables on central systems, 15' with Vector Compacts®, and 10' with Cabin Mates.