Product Description
The Elite ™ Environmental Control Unit
is a microprocessor based controller designed for
the precise monitoring based controller designed for
the precise monitoring of split and self-contained
direct expansion air conditioning systems in marine
environments. The control can also be used with chilled
water air handlers and air called AH-Elite
in this application. The control operated at 115 or
230 volts, each operable at 50 or 60 cycles.
The new Elite control has a sleek, modern Euro
design. It features raised buttons for easy access
and control. The mode button is used to scroll through
the four modes of operation, simplyfying programming.
Decorative snap-on Vimar ® bezels available in
Rondo (shown) and Classica styles, in a variety of
colors and material to match your vessels interior5.
Other Vimar bezel styles are available by special
order.
The Elite display operates with the new Passport®
I/O circuit board. The new circuit board utilizes
state-of-the-art SMT technology. The Elite display
is flash programmable, which will allow for future
software upgrades without the nees to replace the
circuit board.
The assembly has a ground shield to protect against
static interference and RF noise. The circuit is conformally
coated to provide high resisatance to external damage
or corrosion.
A display cable with gold plated phone-type modular
jacks connects the panel to the system controller.
An optional air sensor cable is connected to the circuti
board in the same manner. Non-volatile memory stores
all user-selectable parameters indefinitely during
operation or any power failure situations. Fused circuits
and M.O.V.s (metal oxide varistors) provide component
and board protection.
The Elite control meets or exceeds applicable ABYC,
U.S. Coast Guard Regulations and CE Directives. Features
- Automatic humidity control - reduces moisture when the boat is unattended.
- Cool only, heat only, dehumidify, or automatic mode selection.
- New heater relay allows for optional electric heat.
- Temperature displayed in Fahrenheit or Celsius.
- Multiple fan speed selections - automatic or three manual speeds.
- Cycle fan with compressor or continuous pump operation.
- Compressor time delay staging for multiple unit applications.
- Calibration of fan speed and temperature settings to maintain precise control.
- Blank display lights when desired.
- Controls shaded pole and splir capacitor fan motors.
- Compressor fail-safe protection.
- Programmable de-icing cycle.
- New "Pump Sentry" preotects system if seawater pump fails.
- Built in air sensor for individual cabin heating with chill chasers(AH-Elite).
- Force open water valves for four hours to bleed system (AH-Elite).
Installation
- The circuit board and display cable are factory installed in the electrical box.
- Display panels are mounted with screws for a secure fir. Bezel snaps on, hiding the screws.(5)
- Easy connections using phone-type modular jacks which are shielded and grounded.
SPECIFICATIONS
| Model |
ELITE ENVIRONMENTAL CONTROL |
| Voltage(VAC) |
115 |
230 |
| Cycle(Hz) |
50/60 |
50/60 |
| Phase(Ø) |
1 |
1 |
| |
|
|
| Circuits(1) |
| Compressor
Output(2) |
40A-115VAC |
20A-230VAC |
| R.V. Output(3) |
6A-115VAC |
6A-230VAC |
| Fan Ouput |
6A-115VAC |
6A-230VAC |
| Heater
Output |
30-115VAC |
30A-230VAC |
| Pump Output(2) |
Quarter HP |
Half HP |
| |
| Temperature
Ranges°F(°C) |
| Set Point
Temperature |
65-85(18-29) |
| Display
Temperature |
5-150(-15-66) |
| Air Sensor
Temperature |
5-150(-15-66) |
| Sensor
Accuracy |
±2°F
at 77 °C (±3.6°Cat 25°C) |
| |
|
| Dimensions
in(cm) |
| Display
Panel |
4.41(11.2) W
x 2.96(7.5)H x 1.08(2.7)D |
| Panel
Cut-Out |
3.31(8.4)W
x 2.19(5.6)H |
| Bezel
Size(5) |
4.85(12.3)W
x 3.25(8.3)H |
| |
|
| Cables
Included(4) |
| Display
ft(m) |
VCD: 15(4.6)
CMCD: 10(3.0) CSD:30(9.1) Chiiled Water: 15(4.6) |
| Water
Inlet Sensor |
7' (2.1m) cables
included with some AH-Elite & AH-Passport
I/O kits. |
| |
| Other
Cables Available(4) |
Most Cables Available
in 5' increments |
| Display
ft(m) |
10'-75'(3.0 -
22.9) |
| Alternate
/ Remote Air (optional) |
7' -60'(2.1 -
18.3) |
| Outside
Sir Sensor (optional) |
7' - 50'(2.1-15.2) |
| Pump Sentry
(optional) |
7'-60'(2.1 -
18.3) |
| Water
Inlet Sensor(AH-Elite) |
7' - 60'(2.1
- 18.3) |
- Maximum loads should not exceed 85% of listed output ratings.
- Does not apply to AH-Elite.
- Used as water valve outout in AH-Elite mode.
- Maximum length for display and air sensor cables is 75'.
Maximum length for water inlet sensor cable is 75'.
- Idea type bezels from Vimar sold separately. Dimensions may vary depending on style.
|