Features
Unique Compact Modular Design

  • Increased plenum chambers for maximum efficiency.
  • Easy disassembly for access to components.
Condensate Drain Pan
  • Insulated to prevent sweating.
  • Two 1/2" FPT drain hook-ups.
Blower/Coil Assemblies
  • Quiet, efficient, centrifugal blowers.
  • Rototable between horizontal and vertical configurations.
  • Fully insulated housings.
  • Thermostatic mouting rings enable easy installation of ducting or transition boxes.
  • Coils with enhanced fins and rifles tubing for maximum efficiency.
Quality Assurance
  • Contaminant-free, nitrogen purged assembly procedures.
  • Each unit is pre-checked, test run in all operating modes and leak checked.
  • Charge Guard® protection provides sealed access ports, ensuring environmental protection and system integrity.
  • All units meet or exceed applicable ABYC and U.S. Coast Guard regulations, CE Directives and general AirConditioning and Refrigeration Industry (ARI) standards.

SPECIFICATIONS

Model E4FD /
Z
E6FD /
Z
E9FD /
Z
E12FD /
Z
E16FD /
Z
E24FD /
Z
Capacity (BTU/H - Kcal / H) 4,000 / 1,008 6,000 / 1.512 9,000 / 2,268 12,000 / 3,024 16,000 / 4,032 24,000 / 6,048
Voltage(VAC) 115 VAC - 230 VAC 230 V
Cycle / Phase (Hz /Ø) 50 / 60 Hz - 1Ø
Amperage
115 V 1.9 1.9 2.9 2.9 3.3 N/A
230 V .83 .83 1.4 1.4 1.8 0.8
Air Flow (CFM / M3H) 140/
238
200/
340
300/
509
400/
679
530/
900
800/
1.358
 
Unit Dimensions(in/cm)1
H1 (Height)(2) 9.75/
24.77
10.80/
27.43
10.80/
27.43
12.60/
32.00
13.70/
34.80
16.50/
41.91
H2 (Height)(3) 10.70/
27.18
13.00/
33.02
13.00/
33.02
13.75/
34.93
14.81/
37.62
N/A
D (Depth) 10.10 / 25.65 11.40 / 28.96 11.10 / 28.19 11.20 / 28.45 12.80 / 32.51 15.60 / 39.62
W (Width) 11.40/
28.96
13.20/
33.57
15.50/
39.37
15.50/
39.37
16.80/
42.67
21.25/
53.98
M (Motor) 2.10/
5.33
2.50/
6.35
2.90/
7.37
2.90/
7.37
3.30/
8.38
4.00/
10.16
Supply Duct Diameter 4.0/
10.2
5.0/
12.7
6.0/
15.2
6.0/
15.2
7.0/
17.8
8.0/
20.3
Refrigerant Connections 1/4" x 3/8" 1/4" x
3/8"
1/4" x
3/8"
1/4" x
3/8"
1/4" x
1/2"
3/8" x
5/8"
Drain Connections 1/2" FPT Aluminium
Unit Weight (lbs /kg) 12.3/
5.6
15.4/
7.0
22.1/
10.1
21.5/
9.8
26.1/
11.9
46.0/
21.0
Shipping Weight 20.8/
9.5
24.1/
11.0
30.7/
14.0
30.0/
13.7
34.7/
15.9
54.0/
24.6

  1. Add 2"/5.1 cm to height dimension to allow for duct ring (not included) when blower is installed in its vertical position.
  2. H1 is measured to top of evaporator or blower discharge, whichever is higher.
  3. Height H2 is with blower rotated in field.