Features
Unique Compact Modular Design
- Increased plenum chambers for maximum efficiency.
- Easy disassembly for access to components.
Condensate Drain Pan
- Insulated to prevent sweating.
- Two 1/2" FPT drain hook-ups.
Blower/Coil Assemblies
- Quiet, efficient, centrifugal blowers.
- Rototable between horizontal and vertical configurations.
- Fully insulated housings.
- Thermostatic mouting rings enable easy installation of ducting or transition boxes.
- Coils with enhanced fins and rifles tubing for maximum efficiency.
Quality Assurance
- Contaminant-free, nitrogen purged assembly procedures.
- Each unit is pre-checked, test run in all operating modes and leak checked.
- Charge Guard® protection provides sealed access ports, ensuring environmental protection and system integrity.
- All units meet or exceed applicable ABYC and U.S. Coast Guard regulations, CE Directives and general AirConditioning and Refrigeration
Industry (ARI) standards.
SPECIFICATIONS
| Model |
E4FD /
Z |
E6FD /
Z |
E9FD /
Z |
E12FD /
Z |
E16FD /
Z |
E24FD /
Z |
| Capacity (BTU/H - Kcal /
H) |
4,000 / 1,008 |
6,000 / 1.512 |
9,000 / 2,268 |
12,000 / 3,024 |
16,000 / 4,032 |
24,000 / 6,048 |
| Voltage(VAC) |
115 VAC - 230
VAC |
230 V |
| Cycle / Phase (Hz /Ø) |
50 / 60 Hz
- 1Ø |
| Amperage |
| 115 V |
1.9 |
1.9 |
2.9 |
2.9 |
3.3 |
N/A |
| 230 V |
.83 |
.83 |
1.4 |
1.4 |
1.8 |
0.8 |
| Air Flow (CFM / M3H) |
140/
238 |
200/
340 |
300/
509 |
400/
679 |
530/
900 |
800/
1.358 |
| |
| Unit Dimensions(in/cm)1 |
| H1 (Height)(2) |
9.75/
24.77 |
10.80/
27.43 |
10.80/
27.43 |
12.60/
32.00 |
13.70/
34.80 |
16.50/
41.91 |
| H2 (Height)(3) |
10.70/
27.18 |
13.00/
33.02 |
13.00/
33.02 |
13.75/
34.93 |
14.81/
37.62 |
N/A |
| D (Depth) |
10.10 / 25.65 |
11.40 / 28.96 |
11.10 / 28.19 |
11.20 / 28.45 |
12.80 / 32.51 |
15.60 / 39.62 |
| W (Width) |
11.40/
28.96 |
13.20/
33.57 |
15.50/
39.37 |
15.50/
39.37 |
16.80/
42.67 |
21.25/
53.98 |
| M (Motor) |
2.10/
5.33 |
2.50/
6.35 |
2.90/
7.37 |
2.90/
7.37 |
3.30/
8.38 |
4.00/
10.16 |
| Supply Duct Diameter |
4.0/
10.2 |
5.0/
12.7 |
6.0/
15.2 |
6.0/
15.2 |
7.0/
17.8 |
8.0/
20.3 |
| Refrigerant Connections |
1/4" x 3/8" |
1/4" x
3/8" |
1/4" x
3/8" |
1/4" x
3/8" |
1/4" x
1/2" |
3/8" x
5/8" |
| Drain Connections |
1/2"
FPT Aluminium |
| Unit Weight (lbs /kg) |
12.3/
5.6 |
15.4/
7.0 |
22.1/
10.1 |
21.5/
9.8 |
26.1/
11.9 |
46.0/
21.0 |
| Shipping Weight |
20.8/
9.5 |
24.1/
11.0 |
30.7/
14.0 |
30.0/
13.7 |
34.7/
15.9 |
54.0/
24.6 |
- Add 2"/5.1 cm to height dimension
to allow for duct ring (not included) when blower is
installed in its vertical position.
- H1 is measured to top of evaporator or
blower discharge, whichever is higher.
- Height H2 is with blower rotated in field.
|