Features
Modular Symmetrical Design
- Large plenum chamber for maximum capacity.
- Optimum efficiencies in heat and cool with 3-way valve that assures proper water flow.
- Electric heating option.
Blower Assemblies
- Quickly converts between a vertical or horizontal application.
- Extremely quiet diffused air delivery.
Condensate Drain Pan
- Dual drain connections enhance removal of collected condensation.
- Drain pan is a full 2" high and is completely insulated.
Quality Assurance
- System matched components assure full BTU rating.
- All units meet or exceed applicable ABYC and U.S. Coast Guard regualtions, CE Directives and general Air Conditioning and Refrigeraion
Industry (ARI) standards.
SPECIFICATIONS
| Model (1)
|
AH6K-
BT |
AH9K-
BT |
AH12K-
BT |
AH16K-
BT |
AH18K-
BT |
AH24K-
BT |
| Capacity
(BTU/H) / (Kcal/H) |
6,000/
1,512 |
9,000/
2,268 |
12,000/
3,024 |
16,000/
4,032 |
18,000/
4,536 |
24,000/
6,048 |
| Voltage(VAC) (4)
|
115
VAC - 230 VAC |
| Cycle (2)
|
60 |
| Phase |
1Ø |
| Amperage |
1.8/0.8 |
| GPM/(Liters/Min.) |
1.5/
5.7 |
2.25/
8.5 |
3.0/
11.4 |
4.0/
15.1 |
4.5/
17.0 |
6.0/
22.7 |
| CFM/(M3
/Hr.) |
200/
340 |
300/
510 |
400/
680 |
500/
850 |
600/
1,020 |
700/
1,190 |
| Dimensions
(in/cm)(3) |
| A (Width) |
23.5/
59.7 |
23.5/
59.7 |
30.0/
76.2 |
30.3/
76.2 |
42.5/
108.0 |
42.5/
108.0 |
| B (Depth) |
19.8/
50.2 |
19.8/
50.2 |
19.8/
50.2 |
19.8/
50.2 |
19.8/
50.2 |
19.8/
50.2 |
| C (Height) |
10.0/
25.4 |
10.0/
25.4 |
10.0/
25.4 |
10.0/
25.4 |
10.0/
25.4 |
10.0/
25.4 |
| D (Supply Air Oulet) |
17.0 x 7.0
/ 43.2 x 17.8 |
17.0 x 7.0
/ 43.2 x 17.8 |
25.0 x 7.0
/ 63.5 x 17.8 |
25.0 x 7.0
/ 63.5 x 17.8 |
37.0 x 7.0
/ 94.0 x 17.8 |
37.0 x 7.0
/ 94.0 x 17.8 |
| Return Air Inlet-Sq
Surf. Area |
120 /
774 |
120 /
774 |
170 /
1,097 |
170 /
1,097 |
260 /
1,677 |
260 /
1,677 |
| Water Inlet / Outlet
|
0.5"
FPT brass with 0.625" HB brass |
| Condensate Drains
|
2 @ 0.625" Ø x 2" long pipe. |
| Optional
Heating Elements (4) |
| Max. Heater Size |
1.0KW |
1.5KW |
2.0KW |
2.5KW |
3.0KW |
3.0KW |
| Rating (BTU/H)(KCal/H) |
3,415/
861 |
5,123
/1,291 |
6,830/
1,721 |
8,538/
2,152 |
10,245/
2,582 |
10,245/
2,582 |
| Amperage (115/230
VAC) |
8.6/
4.3 |
13.0/
6.5 |
17.4/
8.7 |
21.8/
10.9 |
26.0/
13.0 |
26.0/
13.0 |
- "Z" at the end of the model number designates 230V, i.e., AH12K-BT designates 115V; AH12K-BTZ designates 230V.
- Full capacity 50 cycle units available upon request.
- BT Series available in vertical or horizontal configuration. Reverse depth and height figures above for vertical configuration.
Specify "H" or "V".
- Optional elements may be mounted internally in blower discharge stream(s). Each heating element is protected with a thermal overload
and a fuse link. Smaller elements may be applied to units except the AH6K-BT units.
|