www.oceanoptions.com
   :: Home
   :: About Us
   :: Products
   :: New Products
   :: Technical Support
   :: Dealer Locator
   :: Contact

6K 16K Condensing units
(Marine Air Systems)

Click here to view Installation Guide


Product Description
Central System Condensing Units are available in capacities ranging 6,000 to 16,000 BTUs, in both reverse cycle and cool only. Each model is available for 115 volt or 230 volt operation, at both 50 cycles and 60 cycles. For larger capacities, see the Multi Ton condensing unit.
High efficiency compressors are incorporated are provide significant reductions in amperage draw. Each unit is hermetically sealed. Pressure switches and thermal overloads afford system protection.
Condener coils are construted of spiral, fluted cupronickel enclosedin a copper shell to provide high corrosion resistance for continual seawater flow. All surface components are constructed of, or coated with, materials resistant to fire and corrosion.
Central System Condensing Units can be installed in any convinient location and are unaffected by vibration, moisture or ambient temperatures up to 140°F.
Features
Symmetrical Base Design

  • Provides optimum space efficiency with 13.13" square footprint.
  • Allows ease in handling and installation.
Electrical Box
  • Moisture resistant design.
  • Internal components are fully serviceable.
Internal Drain Pan
  • Allows for condensation removal.
  • Provides for internal fastening of unit.
  • Seam welded construction promotes structural integrity.
  • Two sets of vibration isolators reduce vibration and ensure quite operation.
Quality Assurance
  • Each unit is pre-charged, test run in all operating models and leak checked.
  • Charge Guard ® preotection provides sealed access ports ensuring environmetal protection ans system integrity.
  • All units meet or exceed applicable ABYC and U.S. Coast Guard regulations. CE Directives and general Air Conditioning and Refrigeration Industry (ARI) standards.
SPECIFICATIONS

Model CS*6K CS*9K CS*12K CS*16K
Capacity (BTU/H)(1) (2) 6,000 9,000 12,000 16,000
Electrical Data(2)  
Voltage(VAC) 115 230 115 230 115 230 115 230
Full Load Amps (FLA) cool 7.0 3.7 6.4 3.2 8.4 4.4 12.2 5.7
Full Load Amps (FLA) heat 7.7 4.0 7.2 3.6 9.2 5.0 13.5 6.8
Locked Rotor Amps 34 20 40 20 50 31 75 36
K.V.A. (Kilo-Volt-Amps) 0.9 0.9 0.8 0.8 1.1 1.2 1.6 1.5
Max. Circuit Breaker (Amps) 20 10 20 10 30 15 40 20
Min. Circuit Ampacity (Amps) 13 8 13 7 17 10 25 12
 
Physical Data:
Unit Dimensions (3) 13.13"/33.34cm W x 13.13" / 33.34cm D x 15.50" / 39.4cm H
Water Inlet / Outlet 5/8" / 1.59 cm O.D.
Base Condensation Drain 5/8" / 1.59 cm O.D.
Base Valves (discharge x suction) 1/4" x 3/8" 1/4" x 3/8" 1/4" x 3/8" 1/4" x 1/2"
Refrigerant R-22 (oz/kg) 20/0.57 21/0.60 24/0.68 24/0.68
Weight (lbs/kg)
Net 56/25.5 64/29.1 66/30.0 66/30.0
Ship 63/28.6 74/33.6 75/34.0 75/34.0

  1. Ratings at 60 Hz operation will be diminished by 17%. Fully rated 50 Hz equipment is available for 220/240 VAC operation.
  2. 60 Hz data given. BTU and electrical data based on a 45° evaporator and 100°F condenser in cool mode, and a 45°F evaporator and 130°F condenser in heat mode.
  3. Unit Height is 12.6"/32.0 cm without electrical box. 'C' at the wnd of model number denotes cool only. Example CSP9KC 'Z' at the end of the model number denotes 230V. Example: CSP6KZ


* P = Passport II Control (CSP)    M = Manual Control (CSM)

Developed by BF Enterprises