PRODUCT DESCRIPTION
The Docksider model of Grunert refrigeration is designed for yachts with
AC power source on board. It is an ideal unit when used in conjunction with
an engine-driven system or for a stand-alone application for smaller boxes.
The Docksider features air and water-cooled condensers for maximum versatility.
Air-cooled refrigeration offers standard efficiencies for use when a vessel
is hauled. Water-cooled refrigeration provides increased efficiencies, and porper
operation in high ambient temperatures.
The Docksider model can cool a number of different box sizes and configurations.
For design assistance, contact your local dealer or the Customer Support Team
at Taylor Made Environmental, Inc.
Docksider condensing units can be installed in any convenient location
and are unaffected by vibration or moisture. All units meet or excced applicable
ABYC and U.S. Coast Guard regulations, CE Directives and General Air Conditioning
and Refrigeration Industry (ARI) standards.
FEATURES High Quality Coponents
Hermetically sealed compressor for quiet, efficient operation.
Vibration isolators incorporated in all mounting platforms for additional noise control.
Replaceable filter/drier.
Sight glass/moisture indicator built in to enable monitoring of system refrigerant charge.
Environmental Considerations
All units have quick disconnect fittings and are pre-charged with refrigerant for ease of installations.
Additional service valve permits refrigerant isolation for drier change.
Utilizes "ozone friendly" refrigerant 404A.
Quality Assurance
Each unit is assembled with a charge of nitrogen to ensure that scale does not form during soldering.
Every unbit is leak checked, test run and shipped pre-charged with refrigerant.
Charge Guard® protection provides sealed access ports to ensure system integrity during handling and installation.
SPECIFICATION
Model
AC416HA
Refrigerant
R-404A
Charge (oz/g)
18/515
Capacity
(BTU/H)(1)
26°F(-3 °C)
1750
0 °F(-18 °C)
1450
-9 °F(-23 °C)
1350
-18 °F(-28 °C)
1100
Compressor
Capacity (HP)
1/4
Voltage (volts)
115
230
Compressor RLA
6.2
3.0
Fan RLA
0.26
0.14
LRA (Locked Rotor AMPs)
40.0
21.0
Maximum Circuit Breaker
15.0
10.0
Minimum Circuit Ampacity
10.0
5.0
Physical
Data
Dimensions
(in/cm)
H (Height)(2)
12.00/30.5
W (Width)
12.00/30.5
D1 (Depth 1)
13.50/34.3
D2 (Depth 2)
15.00/38.1
Weight (lbs/kg)
Net
55/24.95
Ship
65/29.48
BTU/H ratings are the average rate of extraction from hold over plates and are not the capacity of the compressor or
condensing unit. These figures are to be used to determine run times required to maintain box design temperatures.